Push-button panels
The description
Push-button panels (vandal protected) are intended for remote control of lifts.
Functional division:
- Panels of lift cabin control: PCC- 1
- Panels of lift cabin call: PCC-2
- Design variants of PCC - 1-03, PCC- 1-04, PCC- 2-03, PCC- 2-04: metal push-button elements grant "vandal protection". They do not burn out or melt, that helpes to reduces service expenses.
| Characteristics: |
| Rated voltage of the communications, V: |
|
| Direct current, up to 0,5 A |
24 ± 2 |
| Alternating current up to 0,1 A |
220 ± 22 |
| PCC - 1 multipush-button panel, contains a microphone for emmerge call of the dispatcher and a loud speaker capacity not less: |
0,25 W |
| Single push-button panel PCC-2, commutation direct current voltage 0,5 A, V |
24 ± 2 |
|
|
|
|
| Name |
Overall dimencions, mm |
Weight, kg |
| PCC-1-6-04, PCC-1-10-03, PCC-1-10-04 |
460x218x72 |
6,0 |
| PCC-1-14-04, PCC-1-16-03, PCC-1-17-04 |
550x218x72 |
7,5 |
| PCC-2-03, PCC-2-04 |
145x100x78 |
0,8 |
|
|
|
Designed - 03 for devices MDL
Designed - 04 for devices DPLM
^
Illuminated call-out ТС-Ц
The description.
Illuminated call-out (IC) is intended for notification of position and movement direction of the lift cabin, in up to 30 stored buildings. This devise works in a couple with lift management devices of series MDL and DPLM.
Operation principle is based on using of semisegmental electronic indicator.
| Characteristics: |
| Control signals level, V |
20,4 - 26,4 |
| Overall dimensions, mm |
218x90x38 |
| Ambient air temperature, °C |
from 1 up to 45 |
| Relative air humidity at 25 °C, % |
80 |
| Barometric pressure, mm of mercury |
550-800 |
|
|
|
|
| Name |
Number of floors |
Cable length, mm |
Weight, kg |
| ТС-9-Ц-0 |
9 |
1500 |
0,85 |
| ТС-30-Ц-0 |
30 |
1500 |
0,85 |
| ТС-9-Ц-1 |
9 |
3000 |
0,95 |
| ТС-30-Ц-1 |
30 |
3000 |
0,95 |
|
|
|
^
Illuminated call-out
The description
Illuminated call-out (IC) is intended for notification of position and movement direction of the lift cabin, in up to 17 stored buildings.
| Characteristics: |
| Power supply, direct current, V |
24 ± 2,4 |
| Code of managing signals: |
|
| IC - (3... 10) - P |
positional |
| IC - (3... 17) - D |
even-decimal (1-2-4-8) |
| Quantity of served stores: |
|
| The HARDWARE - (3... 10) - P |
from 3 up to 10 |
| The HARDWARE - (3... 17) - D |
from 3 up to 17 |
| Weight, not more, kg |
1,3 |
|
|
|
^
Move/stop switch (MSS)
The description
The switch MSS-11 is used in control circuits of cargo and passenger lifts. Coordinates error is not more than ± 1 mm, that grants an exact stop of lifts on floors.
| Characteristics |
| Number and type of contacts |
1 break contact - open when the shunt is in the backlash of the switch, close when shunt is removed. |
| The rated voltage of a direct current applied to contact, V |
110 |
| The rated current passing through contact, A |
0,06 |
| The basic error of coordinates, not more, mm |
± 1 |
| Overall dimensions, mm |
95x74x55 |
| Weight, not more, kg |
0,38 |
|
|
|