ÈÔ-1002; ÈÔ-1101; ÈÔ-1201; ÈÔ-1301;
ÈÔ-1401; ÈÔ-1501; ÈÔ-1601; ÈÔ-1701;
ÈÔ-1003; ÈÔ-1103; ÈÔ-1203; ÈÔ-1303;
ÈÔ-1403; ÈÔ-1503; ÈÔ-1603; ÈÔ-1703
- Multipurpose
- Wide range
- High sensitive
Multipurpose wide-range high-sensitive unified rows of signal fluctation meters (SFM) are intended for measurement of peak, phase (frequency) fluctuations of quasiharmonic signals of two-poles (generators), the peak and phase fluctuations, combined by four-, six-pole networks into quasiharmonic and continuous sequence of signals pulses in a range of frequencies 5MHz-35,95GHz.
All of the devices in the row use as a basis ÈÔ-1002 or ÈÔ-1003 which solve problems of peak and phase fluctuations measurement in a range of carrier frequencies 5-1070 MHz and are used as systems of processing information for concrete models of MICROWAVE SFM (ÈÔ-1102, ÈÔ-1103, ÈÔ-1202, ÈÔ-1203 ...).
Thus ÈÔ -1002 is used to replenish devices measuring peak and phase fluctuations of continuous signals (for example, ÈÔ -1101, ÈÔ -1201, ÈÔ -1301, etc.). ÈÔ -1003 is used as base model for the devices measuring fluctuations of continuous signals, and also peak and brought phase fluctuations of continuous sequence of signal pulses (for example, ÈÔ-1103, ÈÔ-1203, ÈÔ-1303, etc.).
ÈÔ-1102 consists of:
- Low frequency block (LFB)
- Intermediate frequency block (IFB)
- Secondary power supply (ÂÝÏ-1)
- Spectrum analyzers CK4-56, CK4-58
- Structure of measuring instruments ÈÔ-1102:
- ÈÔ-1102 and the complete set of low frequency filters.
Structure of measuring instruments ÈÔ-1101, ÈÔ-1103, ÈÔ-1201, ÈÔ-1203 ... ÈÔ-1603.
- The specified row of measuring instruments consist of a base model ÈÔ-1002 or ÈÔ-1003, depending on a measured source signal type (continuous or pulse), blocks of converters, blocks of high frequency, blocks oscillators with power supplies, blocks of resonators.
Fluctuations meter ÈÔ 1002
| Characteristics: |
| Input power range, mW |
0,1-500 |
| Range of analyzed frequencies, kHz |
0,02...600 |
| Input KBCH, max |
2,5 |
| Level of self-noises in a range of analyzed frequencies, dB/Hz |
154...170 |
| Working range of frequencies, MHz |
5...1070 |
| Error, max dB |
±3 |
| Mean-time-between-failures, hours |
3000 |
| AC power supply, V/Hz |
220/50; 220/400 |
| Category temperature range, °Ñ |
from 5 up to 40 |
|
|
|
Fluctuations meter ÈÔ 1003
| Òåõíè÷åñêèå õàðàêòåðèñòèêè: |
| Parameters of input pulse signals: |
|
| Repetition rate |
0,22 - 300 kHz |
| Duration |
≥0.5micro sec. |
| Off-duty factor |
< 100 |
|
|
|
^
Copyright © 2003 ÐÓÏ "Ìèíñêèé çàâîä Êàëèáð"
Ïðîäâèæåíèå ñàéòà SunWeb.by
|