Ïåðåêëþ÷èòüñÿ íà ðóññêèé
 
Èô-1002...

ÈÔ-1002; ÈÔ-1101; ÈÔ-1201; ÈÔ-1301;
ÈÔ-1401; ÈÔ-1501; ÈÔ-1601; ÈÔ-1701;
ÈÔ-1003; ÈÔ-1103; ÈÔ-1203; ÈÔ-1303;
ÈÔ-1403; ÈÔ-1503; ÈÔ-1603; ÈÔ-1703

  • Multipurpose
  • Wide range
  • High sensitive

Multipurpose wide-range high-sensitive unified rows of signal fluctation meters (SFM) are intended for measurement of peak, phase (frequency) fluctuations of quasiharmonic signals of two-poles (generators), the peak and phase fluctuations, combined by four-, six-pole networks into quasiharmonic and continuous sequence of signals pulses in a range of frequencies 5MHz-35,95GHz.

All of the devices in the row use as a basis ÈÔ-1002 or ÈÔ-1003 which solve problems of peak and phase fluctuations measurement in a range of carrier frequencies 5-1070 MHz and are used as systems of processing information for concrete models of MICROWAVE SFM (ÈÔ-1102, ÈÔ-1103, ÈÔ-1202, ÈÔ-1203 ...).

Thus ÈÔ -1002 is used to replenish devices measuring peak and phase fluctuations of continuous signals (for example, ÈÔ -1101, ÈÔ -1201, ÈÔ -1301, etc.). ÈÔ -1003 is used as base model for the devices measuring fluctuations of continuous signals, and also peak and brought phase fluctuations of continuous sequence of signal pulses (for example, ÈÔ-1103, ÈÔ-1203, ÈÔ-1303, etc.).

ÈÔ-1102 consists of:
  • Low frequency block (LFB)
  • Intermediate frequency block (IFB)
  • Secondary power supply (ÂÝÏ-1)
  • Spectrum analyzers CK4-56, CK4-58
  • Structure of measuring instruments ÈÔ-1102:
  • ÈÔ-1102 and the complete set of low frequency filters.
Structure of measuring instruments ÈÔ-1101, ÈÔ-1103, ÈÔ-1201, ÈÔ-1203 ... ÈÔ-1603.
  • The specified row of measuring instruments consist of a base model ÈÔ-1002 or ÈÔ-1003, depending on a measured source signal type (continuous or pulse), blocks of converters, blocks of high frequency, blocks oscillators with power supplies, blocks of resonators.

Fluctuations meter ÈÔ 1002

Characteristics:
Input power range, mW 0,1-500
Range of analyzed frequencies, kHz 0,02...600
Input KBCH, max 2,5
Level of self-noises in a range of analyzed frequencies, dB/Hz 154...170
Working range of frequencies, MHz 5...1070
Error, max dB ±3
Mean-time-between-failures, hours 3000
AC power supply, V/Hz 220/50; 220/400
Category temperature range, °Ñ from 5 up to 40

Fluctuations meter ÈÔ 1003

Òåõíè÷åñêèå õàðàêòåðèñòèêè:
Parameters of input pulse signals:
   Repetition rate 0,22 - 300 kHz
   Duration ≥0.5micro sec.
   Off-duty factor < 100




^


Copyright © 2003 ÐÓÏ "Ìèíñêèé çàâîä Êàëèáð"
Ïðîäâèæåíèå ñàéòà SunWeb.by
FACTORY PRODUCTION
Radiomeasuring devices
Ë2-54
Ë2-60
E7-14
E7-15
E7-18
Ocillograph C9-27
Ocillograph C9-8
Ocillograph C8-23
Ocillograph C8-38
Ocillograph C1-142
Ocillographs C1-117/X
Megaohmmeter E6-16
Pulse-voltage voltmeter B4-24/1
Universal power source
Stabilized power source
Currents and voltages source ÈTH
Cymometer ×3-81
Universal measuring (testing) device ÓÏÓ-21
Signals fluctuations meters ÈÔ-5901
Signals fluctuations meters ÈÔ-1002...
Generators of signals Ã3-131
Generators of signals Ã6-46/1
Sound amplifiers
Equipment for lifts
Equipment for poultry keeping
Lighting engineering
Consumer goods