ИФ-1002; ИФ-1101; ИФ-1201; ИФ-1301;
ИФ-1401; ИФ-1501; ИФ-1601; ИФ-1701;
ИФ-1003; ИФ-1103; ИФ-1203; ИФ-1303;
ИФ-1403; ИФ-1503; ИФ-1603; ИФ-1703
- Multipurpose
- Wide range
- High sensitive
Multipurpose wide-range high-sensitive unified rows of signal fluctation meters (SFM) are intended for measurement of peak, phase (frequency) fluctuations of quasiharmonic signals of two-poles (generators), the peak and phase fluctuations, combined by four-, six-pole networks into quasiharmonic and continuous sequence of signals pulses in a range of frequencies 5MHz-35,95GHz.
All of the devices in the row use as a basis ИФ-1002 or ИФ-1003 which solve problems of peak and phase fluctuations measurement in a range of carrier frequencies 5-1070 MHz and are used as systems of processing information for concrete models of MICROWAVE SFM (ИФ-1102, ИФ-1103, ИФ-1202, ИФ-1203 ...).
Thus ИФ -1002 is used to replenish devices measuring peak and phase fluctuations of continuous signals (for example, ИФ -1101, ИФ -1201, ИФ -1301, etc.). ИФ -1003 is used as base model for the devices measuring fluctuations of continuous signals, and also peak and brought phase fluctuations of continuous sequence of signal pulses (for example, ИФ-1103, ИФ-1203, ИФ-1303, etc.).
ИФ-1102 consists of:
- Low frequency block (LFB)
- Intermediate frequency block (IFB)
- Secondary power supply (ВЭП-1)
- Spectrum analyzers CK4-56, CK4-58
- Structure of measuring instruments ИФ-1102:
- ИФ-1102 and the complete set of low frequency filters.
Structure of measuring instruments ИФ-1101, ИФ-1103, ИФ-1201, ИФ-1203 ... ИФ-1603.
- The specified row of measuring instruments consist of a base model ИФ-1002 or ИФ-1003, depending on a measured source signal type (continuous or pulse), blocks of converters, blocks of high frequency, blocks oscillators with power supplies, blocks of resonators.
Fluctuations meter ИФ 1002
| Characteristics: |
| Input power range, mW |
0,1-500 |
| Range of analyzed frequencies, kHz |
0,02...600 |
| Input KBCH, max |
2,5 |
| Level of self-noises in a range of analyzed frequencies, dB/Hz |
154...170 |
| Working range of frequencies, MHz |
5...1070 |
| Error, max dB |
±3 |
| Mean-time-between-failures, hours |
3000 |
| AC power supply, V/Hz |
220/50; 220/400 |
| Category temperature range, °С |
from 5 up to 40 |
|
|
|
Fluctuations meter ИФ 1003
| Технические характеристики: |
| Parameters of input pulse signals: |
|
| Repetition rate |
0,22 - 300 kHz |
| Duration |
≥0.5micro sec. |
| Off-duty factor |
< 100 |
|
|
|
^
Copyright © 2003 РУП "Минский завод Калибр"
|