Ïåðåêëþ÷èòüñÿ íà ðóññêèé
 
Control panel
ÏÓ ÐÓ-1000

Is intended for organization of notification circuits and operative connection circuits, translation of command and broadcasting transfers using 9 basic lines from various sources of a signal: a microphone, the tape recorder, tuner and transmitting line, supports mixing in couple with power amplifiers and remote posts.

Provides:
  • Priority of transfers when working on one line:
    1 - from CAS, 2 - from CP, 3- from RP;
  • Remote turning on RP when broadcasting from CAS and RP, an emergency call and conversation with RP operator without occupying a line;
  • Light indication and sound signal system of operating modes, volume control and timbre of sounding;
  • The control of inputs and outputs of each PA on a corresponding line , using both indicator and speaker.
CP provides:
Warning lights, that notify:
  • About turning CP;
  • About broadcasting from ÖÓÑ;
  • About broadcasting from RP;
  • About broadcasting from microphones 1 and 2, tape recorder or a player, broadcasting line;
  • about broadcasting from CP to a line;
  • About status of PA, connected to a line;
  • About summoning ÍÓ operator from RP;
  • About status of the tape recorder in modes TRANSFER and RECORDING;
  • About conversation of two RP;

The sound signal system that notifies about calling to CP operator from RP.

The control:
  • By means of the indicator - the serial control of inputs of every PA, connected to corresponding line;
  • By means of a loudspeaker - the serial control of inputs and outputs of every the PA, connected to corresponding line.
Commutation:
  • An opportunity of turning on: microphone 1, microphone 2, the tape recorder or a player and a transmitting line, either separately, or all together,
  • An opportunity of an emergency call to a RP operator without occupying a line, and conversation between several RP,
  • An opportunity switching the tape recorder from a mode TRANSFER to a mode RECORDING,
  • An opportunity of turning on/off timbre, noise blanking and tonecompensation regulators for sources of a signal;
  • An opportunity of a selecting any line when indicator and sound control modes are engaged.
Adjustment:
  • loudness of signal sources: microphone 1, microphone 2 and a player both separately or all together (general adjustment);
  • dynamic loudness when sound control mode is engaged or during conversation between RP operators;
  • separate adjustment of a timbre, on both bottom and high frequencies.

CP turn on can be carried out both distantly (when broadcasting from CAS or RP ) and by operator, using a switch " NETWORK ".

Characteristics:
Nominal input voltage of a linear output at nominal input resistance 10 kOhm, mV 775
Nominal input voltage, V
   Microphone input 1x10-3
   Tuner and tape recorder input 0,5
   Broadcasting line input 30
Input resistance, not less than, kOhm
   Microphone input 1
   Tuner and tape recorder input 10
Broadcasting line input 500
Range of rendering frequencies, Hz
   When broadcasting is carried out from microphone inputs 1 and 2 300 ... 6000
   When broadcasting is carried out from broadcasting line, tuner or tape recorder 31,5 ... 16000
Irregularity of frequency characteristic in a range, not more, dB
   (31,5...16000) Hz 2,5
   (300 ... 6000) Hz 3
Ratio signal/ interference, not less, dB
   When broadcasting is carried out from microphone inputs 1 and 2 or tuner 54
   When broadcasting is carried out from broadcasting line or tape recorder 60
AC power supply, V/Hz 220/50
Consumed power, not more, VÀ 100
Overall dimensions, not more, mm 490x360x135
Mass, not more, kg 9,5
Category temperature range, °C 10 up to 35




^


Copyright © 2003 ÐÓÏ "Ìèíñêèé çàâîä Êàëèáð"
Ïðîäâèæåíèå ñàéòà SunWeb.by
FACTORY PRODUCTION
Radiomeasuring devices
Sound amplifiers
Broadcasting center ÐÓ-1000
The power amplifier 100ÓÌ-101Ï
Control panel ÏÓ-ÐÓ-1000
Remote post (RP) ÐÓ-1000
Dynamic speaker unit 0,5 ÃÄØ-15
Equipment for lifts
Equipment for poultry keeping
Lighting engineering
Consumer goods